Thank you for taking interest in Acme Transformer Co part number FS-2-1500, which is listed with the NSN 5950-01-494-1987 and a product description of “Transformer Power.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number FS-2-1500, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Transformer Power part with the NSN 5950-01-494-1987. For example, you can browse other Acme Transformer Co components that were produced under CAGE Code 83920 or listings that belong to FSC 5950 Coils and Transformers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number FS-2-1500 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-494-1987 Item PartTypeName: TRANSFORMER,POWER | 5950 | 014941987 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
852-00509 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CWJS | Winding Operating Voltage | 220.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY AND 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY AND 240.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY |
ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 4.130 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | Winding Operating Voltage | 110.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
CWJS | Winding Operating Voltage | 440.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND PRIMARY AND 460.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND PRIMARY AND 480.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND PRIMARY |
AXGY | Mounting Method | SLOT SINGLE GROUP |
TTQY | Terminal Type And Quantity | 6 COMPRESSION |
AKPV | Mounting Facility Quantity | 4 SINGLE GROUP |
CRBZ | Winding Operating Current | 12.50 AMPERES AC MINIMUM SINGLE COMPONENT SINGLE SECONDARY AND 13.63 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
ABMK | Overall Width | 6.010 INCHES NOMINAL |
ACZB | Frequency Rating | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ABTD | Mounting Slot Width | 0.310 INCHES MINIMUM SINGLE GROUP AND 0.500 INCHES MAXIMUM SINGLE GROUP |
MRC | Decoded Requirement | Clear Text Reply |
ABHP | Overall Length | 6.750 INCHES NOMINAL |
ABKW | Overall Height | 6.030 INCHES NOMINAL |
ACZC | Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AGAV | End Item Identification | AIRCRAFT, B-2 BOMBER (ATB) |
AARG | Reliability Indicator | NOT ESTABLISHED |
ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 5.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | Inclosure Type | FULLY INCLOSED |