Thank you for taking interest in Dickson part number TH300, which is listed with the NSN 6685-01-462-7959 and a product description of “Hygrothermometer Di.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number TH300, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Hygrothermometer Di part with the NSN 6685-01-462-7959. For example, you can browse other Dickson components that were produced under CAGE Code 0P3J6 or listings that belong to FSC 6685 Pressure Temperature And Humidity Measuring And Controlling Instruments with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number TH300 and other desired offerings on Aerospace Spare.
MRC | Criteria | Characteristic |
---|---|---|
STYL | Style Designator | HAND HELD |
ASXH | Voltage Rating In Volts | 9.0 DC NOMINAL |
AGAV | End Item Identification | PACER SPECIAL |
BFQP | Display Digit Quantity | 4 |
BFHZ | Measurement Type | THERMOELECTRICAL CIRCUIT |
BFQN | Display Type | LIQUID CRYSTAL |
ABHP | Overall Length | 7.000 INCHES NOMINAL |
FEAT | Special Features | TEMPERATURE RANGE -22 TO +185 DEG F, -30 TO +85 DEG C; TEMPERATURE ACCURACY +/- 1.8 DEG F (+/-1 DEG C); HUMIDITY RANGE 0 TO 95% RH (NON-CONDENSING);HUMIDITY ACCURACY +/-2 PERCENT FROM 0 TO 60 PERCENT RH; +/-3 PERCENT FROM 61 TO 95PERCENT RH; AVERAGE RESPONSE TIME 3 SECONDS TO MOVE 60 PERCENT OF SCALE; CALCULATED DEW POINT RANGE -20 TO +120 DEG F; -30 TO +50 DEG C; CALCULATED DEW POINT ACCURACY +/-2 DEG C (+/-3 DEG F) FROM 30 TO 95 PERCENT RH; ONE 9 VOLT BATTERY; NUMERAL HEIGHTH .9 INCHES; STORES 16 READINGS |
BHMC | Case Type | CARRYING CASE W/HANDLE |
MRC | Decoded Requirement | Clear Text Reply |
BHMW | Measurement Range | -30.0/+85.0 DEG CELSIUS AND -22.0/+185.0 DEG FAHRENHEIT AND +0.0/+95.0 PERCENT RELATIVE HUMIDITY |
BGJN | Switch Type And Quantity | 8 PUSH BUTTON |
ABMK | Overall Width | 2.750 INCHES NOMINAL |
SPCL | Special Test Features | COMES WITH ONE POINT NIST TRACEABLE CERTIFICATION OF CALIBRATION |
ABFY | Overall Depth | 1.350 INCHES NOMINAL |
CXCY | Part Name Assigned By Controlling Agency | THERMOHYROMOTER; TEMPERATURE/HUMIDITY/DEW POINT INDICATOR |
MATT | Material | PLASTIC OVERALL |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote