Thank you for taking interest in Eaton Corporation part number AM3333HEMG6-3-250-4-50, which is listed with the NSN 5925-01-070-6244 and a product description of “Circuit Breaker.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number AM3333HEMG6-3-250-4-50, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Circuit Breaker part with the NSN 5925-01-070-6244. For example, you can browse other Eaton Corporation components that were produced under CAGE Code 74193 or listings that belong to FSC 5925 Circuit Breakers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number AM3333HEMG6-3-250-4-50 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-070-6244 Item Description: CIRCUIT BREAKER | 5925 | 010706244 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM3333HEMG6-3-250-4-50 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 4 |
CSSX | Switch Current Rating And Type In Amps | 2.5 AC AND 1.0 DC |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
PKWT | Unpackaged Unit Weight | 12.750 OUNCES |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 8 THREADED HOLE |
CQSM | Switch Location And Position Designation | EXTERNAL AT POLE ONE |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
AJEC | Boss Height | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
CPRQ | Reset Method | MANUAL |
CPRT | Manual Actuator Type And Quantity | 4 TOGGLE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRX | Actuator Position Designation | AT EACH POLE |
ADAT | Body Width | 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, THREE, AND FOUR LINKED |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND 50.0 DC |
CBBL | Features Provided | SLIDING BAR INTERLOCK |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
THSD | Thread Series Designator | UNC |
AJWX | Mounting Surface To Terminal End Distance | 1.492 INCHES MINIMUM AND 2.331 INCHES MAXIMUM |
ADAQ | Body Length | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
MRC | Decoded Requirement | Clear Text Reply |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 8 THREADED STUD |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES AC ALL LOCATIONS |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CRTK | Switch Terminal Type | TURRET |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
CMLP | Thread Quantity Per Inch | 32 |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT AND HERMETICALLY SEALED |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote